How to Install Air Admittance Valves Atherton

A valve, D, which is under a light spring pressure, is held closed during times of non activity in the drainage system. The positive air pressure of the room holds the valve down as well as the spring. When the toilet is flushed, the turbulence and gravitational pull of the water to the manhole below causes a negative pressure within the pipework.

Andy Sutton Combi Installations
01942 878101
3 Hillock Place
Manchester
B T Gardener
01617 902639
4 Oriole Drive
Manchester
N S Heating Services
01942 673335
3 Tarnway
Warrington
A J Hesketh Heating Engineer
01204 690279
178 Victoria Road
Bolton
Domestic Gas Services (Bolton)
01204 695028
70 Church Street
Bolton
Thomas Terrence Leach Heating & Plumbing
01942 678459
2 Kenwood Close
Leigh
Parr And Markland
01204 495313
5 Valletts South Buildings
Bolton
Booth Imperial Ltd.
01204 797650
Rink House
Bolton
A K M Heating Ltd.
01942 274927
11-Oct
Warrington
Hydrofan Heating Co.
01204 574997
5 Manchester Road
Bolton
Data Provided by:
 
Provided By: 

How to Install Air Admittance Valves

Commonly called Durgo valves, air admittance valves are designed to decrease the number of pipes that need to penetrate the roof and walls of a property. They reduce the number of parts required to ventilate a soil system and do not compromise the performance.

A valve, D, which is under a light spring pressure, is held closed during times of non activity in the drainage system. The positive air pressure of the room holds the valve down as well as the spring. When the toilet is flushed, the turbulence and gravitational pull of the water to the manhole below causes a negative pressure within the pipework. This opens the Diaphragm A and valve B allowing fresh air to be sucked in through the side vents C and down into the system. The equalisation of pressure prevents the foul air from escaping and the water seals in the traps (bath, toilet and basin) from escaping.

Valve Closed

Closed Valve

Valve Open

Open Valve

Air admittance valves, when installed, must finish above the highest flood level of the space the valve is in...I.E. If the valve is in the same room as a wash hand basin, it must be higher than the overflow of that basin. This is so the pressure equalisation can occur without breaking the water in the traps.

Toilet Air Admittance Valve/p>

Air admittance valves are easily fitted and slip onto the top of the soil and vent pipe. The use of air admittance valves are governed by building regulations and cannot be used in all cases. Please check these regulations before attempting an installation and see our guide to the building regulations, approved document H, in the projects section

Click here to read more from DIY Doctors

Press Complaints Commission